Product classification
IP65 Waterproof UPS control Cabinet
Key words:
Classification:
Distribution Box
- Detailed description
-
- Commodity name: IP65 Waterproof UPS control Cabinet
Designed specifically for outdoor and harsh, humid environments, this UPS system protection and control center integrates the UPS (uninterruptible power supply) host, battery management, power distribution protection, and environmental adaptability. With IP65-rated waterproof and dustproof protection as its core standard, it is suitable for outdoor communication base stations, data center backup power supplies, outdoor charging stations, and industrial outdoor equipment. It ensures stable UPS system operation in rainy, humid, and dusty environments, enabling seamless power failure switching and continuous power supply. It serves as a "power safety barrier" for critical outdoor equipment.
Core Positioning
Designed specifically for outdoor and harsh, humid environments, this UPS system protection and control center integrates the UPS (uninterruptible power supply) host, battery management, power distribution protection, and environmental adaptability. With IP65-rated waterproof and dustproof protection as its core standard, it is suitable for outdoor communication base stations, data center backup power supplies, outdoor charging stations, and industrial outdoor equipment. It ensures stable UPS system operation in rainy, humid, and dusty environments, enabling seamless power failure switching and continuous power supply. It serves as a "power safety barrier" for critical outdoor equipment.Core Advantages: IP65 Protection + UPS System Compatibility
1. Strict IP65 Waterproof and Dustproof Design
Complete dustproof and high-pressure waterproof: Complies with the GB/T 4208-2017 "Degrees of Protection of Enclosures (IP Code)" standard. The IP65 rating means:
Level 6 Dustproof: The cabinet interior is completely isolated from dust intrusion, preventing dust accumulation from causing short circuits in UPS components and heat dissipation failure;
Level 5 Waterproof: Withstands high-pressure water jets from any direction (spray nozzle diameter 6.3mm, water pressure 0.07-0.1MPa, distance 3m), eliminating the risk of water intrusion during heavy rain or shower cleaning. Sealing Details:
The cabinet doors utilize double-layer EPDM sealing strips with a temperature resistance range of -40°C to 120°C and an aging lifespan of 10 years or more, preventing water seepage between the door gaps.
The cable holes/connections are equipped with brass waterproof glands (IP68 protection rating), ensuring gap-free cable entry and preventing moisture from seeping through the cables.
The cabinet top features a 15-20° sloped rain shield with folded edges to prevent rainwater from running down the sides and into the door gaps.
A concealed drain hole (with a dust plug) is provided at the bottom to quickly drain condensation or small amounts of accidental water ingress, preventing internal water accumulation and corrosion of components.2. UPS System-Specific Design
Structural Compatibility: The cabinet features a reserved UPS mounting area (compatible with mainstream 1kVA-20kVA UPS models) with adjustable mounting brackets (height/width adjustable within ±50mm). It also includes space for a battery pack (supports lead-acid and lithium battery modules, and supports UPS backup times of 1-8 hours).
Electrical Integration: A built-in UPS-specific power distribution unit, including an input circuit breaker, output circuit breaker, and leakage protection device, allows for direct connection between the mains input and load output, eliminating the need for a separate distribution box.
Seamless Switching Guarantee: Internal cabinet wiring utilizes flame-retardant copper busbars (with a current carrying capacity that matches the UPS power), minimizing line losses and ensuring that the UPS can switch to the next power source within 10ms in the event of a mains power outage, preventing load loss. 3. Environmental Weathering and Safety Protection
Weather-resistant material: The main body is constructed of 304 stainless steel (for general outdoor use) or 316L stainless steel (for coastal/chemical zones, salt spray resistant for over 5,000 hours). The steel plate is 1.5-2mm thick and is hail-resistant (25mm diameter hailstones will not deform after falling from a height of 10m). It is also UV-resistant (the surface is sprayed with a UV-resistant coating, which will not fade or crack under long-term exposure).
Wide Temperature Compatibility: A built-in intelligent temperature control system, including a heating film (automatically activates below -20°C) and an axial-flow cooling fan (automatically activates above 40°C), maintains an internal temperature of 15°C-35°C, preventing UPS battery capacity degradation caused by low temperatures and capacitor bulging caused by high temperatures.
Multiple Safety Protections:
Overvoltage/Overcurrent Protection: When the mains voltage is abnormal or the load is overloaded, the input circuit breaker automatically trips to protect the UPS host.
Fire Protection: An integrated temperature sensor (accurate ±0.5°C) and smoke alarms. Upon detecting abnormally high temperatures or smoke, the mains power input is immediately cut off and an audible and visual alarm is triggered.Anti-electric shock design: The cabinet internally isolates high and low voltage circuits (using PA66 insulation partitions), and the cabinet door features a "power off, open door" interlock. This automatically disconnects the internal high-voltage circuit when the door is opened, preventing electric shock during operation and maintenance. 4. Intelligent Operation and Maintenance and Convenience
Status Visualization: The cabinet door features a highly transparent acrylic viewing window, allowing direct access to UPS indicators (mains/battery/fault status). An LED display on the cabinet side provides real-time display of key parameters such as mains voltage, UPS output current, and battery SOC (remaining charge).
Remote Monitoring: A reserved RS485/4G communication port allows access to remote monitoring platforms (such as power monitoring systems). This allows for remote viewing of UPS operating data, parameter settings, and receipt of fault alerts (such as low battery and UPS overload), reducing on-site maintenance visits.
Convenient Operation and Maintenance: The cabinet door features a double-opening design with an opening angle of ≥120°. The internal components are arranged with ample operating space (maintenance access width ≥300mm). The battery area features a tiered drawer, allowing battery replacement without disassembling the UPS, improving operation and maintenance efficiency by 50%.Core Categories
By Installation Method
Floor-standing: Features adjustable galvanized feet (height adjustment range 0-50mm) and a bottom ventilation and dust screen. Suitable for outdoor ground-mounted installation (e.g., near base stations or charging stations).
Semi-recessed: The bottom and sides can be recessed into the ground or wall, leaving only the door exposed. This saves space and is suitable for outdoor installations with limited space (e.g., near streetlight control boxes).
Why you can trust Shouke Yuantuo
Instant Quote
If your consultation contains clear information, the offer is usually delivered within a few hours.
Industry experience
Our engineers have accumulated a wealth of experience. We can handle more types of projects.
Guaranteed quality and quantity
It has advanced computer CAD, Solidworks development and design, modern production lines, perfect testing equipment and a set of scientific management system.
500 projects delivered
Since our inception in 2019, we have sent over 500 projects to customers worldwide and we have received numerous positive reviews.
FAQ
Frequent tripping
Usually it is overloaded or shorted.Unplug all electrical appliances in the circuit first and then try to push the gate. If it is successful, plug back the appliances one by one to find the source of the fault; if it is still tripped, you need to check the line.
The leakage protector cannot be closed
It shows that there are hidden dangers of leakage.First press the “reset” button on the protector, and then try to close the gate.If it still can't be closed, it means that the circuit or electrical appliances are leaking, and you need to power off and contact an electrician for maintenance.
The distribution box has an abnormal sound or burnt smell
Immediately turn off the main switch and cut off the power!This is a danger signal of virtual connection, overheating or ablation of the line. Be sure to ask a professional electrician for immediate maintenance.
The switch is loose and the identification is unclear
Aging or damage to the switch can easily lead to control failure.The electrician should be contacted to replace the new switch and re-mark the circuit to ensure the safety of electricity consumption and facilitate future management.
Product inquiry
Note: Please leave your E-mail and our professionals will contact you as soon as possible!