Product classification
Inspection fire control cabinet
Key words:
Classification:
Water pump control cabinet
- Detailed description
-
- Commodity name: Inspection fire control cabinet
The inspection cycle can be manually/automatically set as required; it has protection functions such as overvoltage, undervoltage, phase loss, phase failure, phase error, overtemperature, overcurrent, and overload.
Product Introduction:
The inspection cycle can be manually/automatically set as required; it has protection functions such as overvoltage, undervoltage, phase loss, phase failure, phase error, overtemperature, overcurrent, and overload.
Parameter description:
Control motor power: 15 ~ 250KW
Control voltage: 380V
Frequency: 50Hz
Number of control pumps: 1~8
Application areas:
Automatic control of domestic and industrial water supply and drainage, automatic control of fire fighting, spray and booster pumps, air conditioning cold and hot water circulating pump system, control and start of other AC motors.
Performance characteristics:
Inspection cabinet shall be designed and produced according to national standard GB27898-2011 and GB-50972-2014 standard;
The fire inspection cabinet can control the low-frequency and low-speed self-operation inspection of the fire pump, spray pump and stabilized pressure pump. The inspection cycle and inspection time can be adjusted arbitrarily according to the working conditions;
Equipped with international brand PLC, stable performance, safe and reliable; using frequency conversion governor inspection pump, starting current is small, low speed, small impact on machinery; low power, high efficiency and energy saving;
Three pump-starting modes of automatic, manual and long-distance pump-starting are adopted, with manual operation priority. When the main pump fails, the standby pump is automatically put into operation. Equipped with RS485 standard communication interface, it can be networked with the fire control room to realize remote fire control monitoring;
The equipment has the functions of sound and light alarm and fault memory, and can store 20000 pieces of fault information. The Chinese touch screen is used as the man-machine interface, which is convenient, simple and intuitive to operate. It can memorize faults such as short circuit, phase loss, overcurrent, overvoltage, undervoltage and communication, which is convenient for personnel to repair and operate;
In case of fire signal during patrol inspection, immediately exit patrol inspection, and immediately start fire hydrant pump and spray pump.
Why you can trust Shouke Yuantuo
Instant Quote
If your consultation contains clear information, the offer is usually delivered within a few hours.
Industry experience
Our engineers have accumulated a wealth of experience. We can handle more types of projects.
Guaranteed quality and quantity
It has advanced computer CAD, Solidworks development and design, modern production lines, perfect testing equipment and a set of scientific management system.
500 projects delivered
Since our inception in 2019, we have sent over 500 projects to customers worldwide and we have received numerous positive reviews.
FAQ
Frequent tripping
Usually it is overloaded or shorted.Unplug all electrical appliances in the circuit first and then try to push the gate. If it is successful, plug back the appliances one by one to find the source of the fault; if it is still tripped, you need to check the line.
The leakage protector cannot be closed
It shows that there are hidden dangers of leakage.First press the “reset” button on the protector, and then try to close the gate.If it still can't be closed, it means that the circuit or electrical appliances are leaking, and you need to power off and contact an electrician for maintenance.
The distribution box has an abnormal sound or burnt smell
Immediately turn off the main switch and cut off the power!This is a danger signal of virtual connection, overheating or ablation of the line. Be sure to ask a professional electrician for immediate maintenance.
The switch is loose and the identification is unclear
Aging or damage to the switch can easily lead to control failure.The electrician should be contacted to replace the new switch and re-mark the circuit to ensure the safety of electricity consumption and facilitate future management.