Product classification
Ea Explosion proof ElectricalMeter Shell
Key words:
Classification:
Outdoor enclosure
- Detailed description
-
- Commodity name: Ea Explosion proof ElectricalMeter Shell
The Ea explosion-proof electrical enclosure (including general electrical models and meter-specific models) is a safety protection carrier specially designed for electrical equipment and electric meters. It corely addresses the electrical safety protection needs in flammable and explosive environments. It is widely applicable to scenarios such as industrial workshops, chemical sites, and civil power distribution rooms. Through the dual guarantees of structural design and material technology, it builds a "safety barrier" for internal electrical components.
The Ea explosion-proof electrical enclosure (including general electrical models and meter-specific models) is a safety protection carrier specially designed for electrical equipment and electric meters. It corely addresses the electrical safety protection needs in flammable and explosive environments. It is widely applicable to scenarios such as industrial workshops, chemical sites, and civil power distribution rooms. Through the dual guarantees of structural design and material technology, it builds a "safety barrier" for internal electrical components.
Core technology and performance advantages
As an explosion-proof protective product, its core competitiveness is concentrated in two dimensions: "safety protection" and "durability", which are specifically reflected in the following four points:
1. The explosion-proof level meets the standard and is suitable for multi risk environments
Explosion proof principle: Adopting a "flameproof" design (in accordance with GB 3836.2 national standard or corresponding international IEC 60079 standard), the shell can withstand the explosive pressure of flammable and explosive gases/dust inside, and at the same time, through gap sealing structures (such as joint surfaces and threaded joint surfaces), the explosion flame is prevented from spreading outward, avoiding chain explosions in the external environment.
Common explosion-proof levels: default to Ex d IIB T4 Ga (can be customized according to requirements for higher levels such as Ex d IIC T6), covering most industrial flammable and explosive environments (such as methane, propane, and dust environments).
2. High strength material, durable and resistant to manufacturing
Mainstream materials: 304 stainless steel or die cast aluminum alloy (surface treated with spray coating/anodizing) are selected, each with its own advantages:
304 stainless steel: resistant to acid and alkali corrosion, UV aging, suitable for outdoor and highly corrosive chemical environments;
Die cast aluminum alloy: lightweight (about 40% lighter than stainless steel), good heat dissipation, suitable for indoor industrial control cabinets, meter boxes and other scenarios that require weight.
Structural strength: The shell wall thickness is ≥ 3mm, and the corners are designed with circular arc transitions. The impact resistance performance reaches IK10 level (can withstand 10J energy impact, and about 1kg of weight can fall from a height of 1m without damage), avoiding shell rupture caused by external force collision.
3. Comprehensive protection, taking into account both internal and external security
In addition to the core explosion-proof function, it also has multi-dimensional protection capabilities to ensure the long-term stable operation of internal components:
Dustproof and waterproof: the protection level can reach IP65 (some customized models can reach IP66), which can completely prevent dust intrusion, and prevent jet flow scouring (such as outdoor rainstorm, workshop cleaning water);
Anti corrosion/anti rust: The surface of the metal material has undergone anti-corrosion treatment, and the salt spray test has lasted for more than 480 hours (equivalent to outdoor use for more than 5 years without obvious rust);
Heat dissipation design: Some styles have reserved heat dissipation holes on the side/top of the shell (with explosion-proof sealing structure), or use hollow heat dissipation ribs to avoid performance degradation caused by long-term high-temperature operation of internal electrical components.
4. Humanized design, suitable for installation and maintenance
Convenient opening and closing structure: adopting explosion-proof bolts or quick snap design, which not only meets the requirements of explosion-proof sealing, but also facilitates the later opening of the shell for component maintenance and meter replacement;
Reserved interface: A cable entry device (explosion-proof gland) is pre-set on the side of the shell, which can flexibly choose different specifications of interfaces according to the wiring requirements of electrical components, avoiding damage to the explosion-proof structure caused by later openings;
Clear identification: The surface of the shell is laser engraved with explosion-proof markings (Ex), protection level (IPXX), applicable temperature range (such as -20 ℃~+60 ℃) and other information, which meets industry compliance requirements and is easy to identify and manage on site.
Product core values and user benefits
Safety compliance: Meet national explosion-proof electrical equipment safety standards, help users pass safety inspections in industries such as chemical and coal mining, and avoid safety accidents and regulatory penalties caused by inadequate protection;
Extend equipment life: Isolate dust, water vapor, and corrosive media from electrical components and meters, reduce the probability of component failure, and extend the service life of internal equipment by more than 30%;
Reduce maintenance costs: High strength materials and anti-corrosion design reduce the frequency of shell replacement; Convenient opening and closing and wiring design, reducing later maintenance time (50% more efficient than traditional shell maintenance).
Selection suggestions
If the scene is outdoor or highly corrosive in the chemical industry (such as by the sea or in a chemical plant), priority should be given to using 304 stainless steel material, IP66 protection, and Ex d IIC rating;
If the scene is an indoor industrial workshop or civil distribution room: optional die-casting aluminum alloy material+IP65 protection+Ex d IIB level, balancing cost and performance;
If suitable for precision electric meters and smart electrical components: it is recommended to choose a style with a heat dissipation structure to avoid high temperatures affecting measurement accuracy or component performance.
Why you can trust Shouke Yuantuo
Instant Quote
If your consultation contains clear information, the offer is usually delivered within a few hours.
Industry experience
Our engineers have accumulated a wealth of experience. We can handle more types of projects.
Guaranteed quality and quantity
It has advanced computer CAD, Solidworks development and design, modern production lines, perfect testing equipment and a set of scientific management system.
500 projects delivered
Since our inception in 2019, we have sent over 500 projects to customers worldwide and we have received numerous positive reviews.
FAQ
Frequent tripping
Usually it is overloaded or shorted.Unplug all electrical appliances in the circuit first and then try to push the gate. If it is successful, plug back the appliances one by one to find the source of the fault; if it is still tripped, you need to check the line.
The leakage protector cannot be closed
It shows that there are hidden dangers of leakage.First press the “reset” button on the protector, and then try to close the gate.If it still can't be closed, it means that the circuit or electrical appliances are leaking, and you need to power off and contact an electrician for maintenance.
The distribution box has an abnormal sound or burnt smell
Immediately turn off the main switch and cut off the power!This is a danger signal of virtual connection, overheating or ablation of the line. Be sure to ask a professional electrician for immediate maintenance.
The switch is loose and the identification is unclear
Aging or damage to the switch can easily lead to control failure.The electrician should be contacted to replace the new switch and re-mark the circuit to ensure the safety of electricity consumption and facilitate future management.
Product inquiry
Note: Please leave your E-mail and our professionals will contact you as soon as possible!